27kV Recloser China, MV Outdoor Recloser Automatic Circuit Recloser | Liyond
Home/Outdoor High-Voltage Switchgear/Automatic Circuit Recloser/27kV Outdoor MV Auto Recloser Automatic Circuit Reclosers

27kV Outdoor MV Auto Recloser Automatic Circuit Reclosers

The LYVZ27 27kV reclosers are built for demanding grid automation needs. With a high-capacity magnetic actuator, these units ensure synchronized vacuum interruption across all phases. The unibody epoxy resin housing delivers outstanding insulation, even in polluted or wet environments.
Each unit features a powder-coated stainless tank and external mechanical status indicator. Operators can safely switch to open position with a hot stick through the accessible yellow pull ring.
With support from the BC300/BC500 controller, these 27kV outdoor reclosers enable remote operation, multiple reclosing strategies, and fast fault response—ideal for utilities moving toward smart grid infrastructure.

Electrical ProductsElectrical Products

Technical Parameters of 27kV Outdoor Automatic Circuit Reclosers

Item LYVZ27-630-12-N LYVZ27-800-12-N LYVZ27-630-16-N LYVZ27-800-16-N LYVZ27-630-16-H LYVZ27-800-16-H
Rated continuous current(Ir/A) 630 800 630 800 630 800
Rated short-circuit making current(Tk/s) 3 3 3 3 3 3
Rated duration of short-circuit (Isc/kA) 12.5 12.5 16 16 16 16
Rated short-circuit breaking current (Ima/kA) 31.5 31.5 40 40 40 40
Rated lightning impulse withstand voltage (Up/kV) 125 125 125 125 170 170
Rated short-duration P.F. withstand voltage (Ud/kV) 60 60 60 60 70 70
Impedance μΩ between (μΩ) 60 60 60 60 60 60
Creepage distance phase-to-earth (mm) 960 960 960 960 1290 1290
Clearance phase-to-phase(mm) 320 320 320 320 320 320
Minimum clearance, phase-to-earth (mm) 270 270 270 270 350 350
Weight (kg) 140 140 140 140 155 155
Line charging current (A) 5 5 5 5 5 5
Cable charging current (A) 25 25 25 25 25 25
Max. interrupting time/max closing(ms) 40/60 40/60 40/60 40/60 40/60 40/60

Overall Outline Dimension of 27kV OutdoorAutomatic Circuit Reclosers

LYVZ27_27kV Pole-Mounted Automatic Circuit Recloser drawing

Recloser Installation Diagram

No. Item unit A B C D E F
1 15.5kV mm 360 380 910 580 310 1000
2 27kV mm 360 380 910 580 310 1000
3 38kV mm 380 380 1030 640 310 1000

Controller Description of 27kV Outdoor Automatic Circuit Reclosers

Recloser ControllerThe Microprocessor-based recloser controller provides protection, control, monitoring, instrumentation and metering with integrated input and output logic, data logging & fault report.
Communication functionality of the controller is achieved via electrical RS485 port for remote connection. Additional rear ports including RS232 are available for selection.
The Feeder Terminal Unit(FTU) is the core of controller. To prevent any damage to FTU from emergency, the control cubicle contains auxiliary power supply of batteries for uninterruptible power supply, electronic boards and circuit breakers.
A series of protection functions can be set via screen display

Get in Touch with Liyond

We're here to help! Connect with our team for expert support and personalized solutions.

Power your projects with long-lasting switchgear and switchgear components from Liyond.

We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.          Privacy Policy