Epoxy Resin Spouts Embedded Poles for ABB VD4 Vacuum Circuit Breaker
-
Vacuum circuit breaker pole, relates to a kind of high voltage vacuum switch with arc extinguishing or arc prevention device. With epoxy resin shell, vacuum interrupter chamber and other parts of the primary conductive circuit, vacuum interrupter chamber and other parts of the primary conductive circuit with epoxy resin cast into the shell, dynamic conductive block and the lower outlet terminal with spring coupling. The assembly process is simplified, the insulation reliability is high, from external forces and external environmental pollution, eliminating the use of ceramic material vacuum interrupter chamber and the use of epoxy resin casting shell between the contraction force inconsistent stress, to avoid damage to the vacuum interrupter chamber or epoxy resin casting body. Because of the sliding connection method of contact finger spring between the dynamic conductive block and the lower outlet terminal, the structure is simple and the contact resistance is small, especially suitable for the case of high current, which can be used for the control and protection of electrical equipment in power stations, distribution stations and substations, and suitable for frequent operation places.
Features
1.VD4 embeded poles, ABB similar, rated voltage 12KV/24KV, 630A
2.Prompt delivery
3.Competitive price
4.well and good quality -
Parameters of solid seal pole column
MAIN TECHNICAL SPECIFICATION UNIT SPECIFICATION Rated voltage kV 12/24 Rated current A 630 Rated frequency Hz 50/60 Short-duration(1min)power frequency withstand voltage kV 48 Lightning impulse withstand voltage kV 95 Rated short-circuit breaking current kA 20 Rated peak withstand current kA 50 Rated short-circuit making current kA 50 Rated short-time withstand current kA 20 Rated duration of short-circuit S 4 Rated breaking current of single capacitor bank A 400 Rated breaking current of back to back capacitor bank A 400 Rated operating sequence O-0.3s-CO-180s-CO Breaking operations of rated short circuit breaking current Time 30 Mechanical endurance Time 20000 Contact self-close force N 80±50 Force required to hold contacts open at full stroke N 150±50 Circuit resistance at lower limit of rated contact force mΩ ≤ 35 Contact limit erosion mm 3 Gas pressure inside vacuum interrupter Pa ≤ 1X10-3 Partial discharge Pc ≤ 5 Weight of moving parts Kg Weight of vacuum interrupter embedded poles Kg Mechanical data required for the matched vacuum switchgear
MAIN TECHNICAL SPECIFICATION UNIT SPECIFICATION 630 Clearance between open contacts mm 9±1 Average opening speed m/s 1.1±0.15 Average closing speed m/s 0.7±0.2 Rated contact pressure N 2000±200 Contact bouncing duration at closing operation ms ≤ 2 Out of simultaneity of contact closing and opening ms ≤ 2 Bouncing back amplitude of opening contact mm ≤ 3 -
Information for solid seal pole column
From the development of insulation on breakers, it can be divided into three generations: air, composite and solid insulation. And so-called solid insulation means solid seal pole column, which might represent the great advancement of insulation on vacuum breakers. Since the epoxy can be used to replace the insulating and mechanical supports, the breakers therefore become compact and simple and are able to service under humid and dusty conditions. When the external insulation of miniature chambers in air condition fail to fulfill the requests of specifications, solid seal pole column are therefore introduced and now become one of the most applicable ways in the field of medium voltage breakers either at home or abroad.
If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day.