72.5kV-550kV Resin Impregnated Paper (RIP) Dry-Type Transformer Bushings - Liyond
Home/Power Transformer/RIP Bushing/72.5kV-550kV Resin Impregnated Paper (RIP) Dry-Type Transformer Bushings

72.5kV-550kV Resin Impregnated Paper (RIP) Dry-Type Transformer Bushings

Our Resin Impregnated Paper (RIP) dry-type condenser bushings are engineered for high-performance power transformers and reactors. These oil-to-air bushings function as critical current-carrying conductors for high, medium, and low voltage sides, providing superior insulation against the transformer tank shell.

Electrical ProductsElectrical Products

Key Technical Advantages of Resin Impregnated Paper (RIP) Dry-Type Condenser Bushings

1.Dry-Type Construction: Utilizes advanced Resin Impregnated Paper (RIP) technology for a maintenance-free, explosion-proof design.

2.Flexible Installation: Capable of being installed at any angle to suit diverse substation configurations.

3.Extreme Temperature Resilience: Reliable operation within an ambient temperature range of -45°C to +60°C.

4.High Altitude Compatibility: Standard design for 1000m altitude, with customizable correction factors for higher elevations.

Technical Specifications

Table I: Electrical Performance of Oil-to-Air Dry-Type Condenser Bushings for Transformers/Reactors

Nominal System Voltage (Un) kV 35 66 110 132 150 220 330 420 500
Rated Voltage (Ur) kV 40.5 72.5 126 145 170 252 363 420 550
Highest Phase Voltage of Equipment (Ur/√3) kV 23.5 42 73 84 98.5 146 210 242 317
60s Power-Frequency Withstand Voltage Dry kV (r.m.s) 95 155 255 305 355 505 625 695 870
Wet kV (r.m.s) 80 140 230 275 325 460 535 680 790
Lightning Impulse Withstand Voltage Full Wave kV (Peak) 200 325 550 650 750 1050 1175 1425 1800
Chopped Wave kV (Peak) 635 750 865 1210 1495 1639 2070
Switching Impulse Withstand Voltage (Dry or Wet) kV (Peak) 850 950 1050 1300
Dielectric Loss Angle Tangent % Increment (Not Greater Than) 1.05Ur/√3 · Ur: 0.1
Max Value (Not Greater Than) 40.5kV ~ 363kV 1.05Ur/√3 · Measured: 0.6
Max Value (Not Greater Than) 420kV ~ 550kV 1.05Ur/√3 · Measured: 0.5
Partial Discharge at U_r (Not Greater Than) pC 10

Table II – Bending Test Load Table

Rated Voltage Ur (kV) Rated Current Ir A
 Ir ≤ 800 A 800 < Ir ≤ 1600 A 2000 ≤ Ir ≤ 2500 A Ir ≥ 3150 A
Bending Test Load N (N)
40.5 1000 1250 2000 3150
72.5 ~ 145 1000 1250 2000 4000
170 ~ 252 1250 1600 2500 4000
≥ 363 2500 2500 3150 5000

Product Dimensions

We offer specialized models for 72.5kV to 550kV applications with various current ratings and connection types.

72.5kV-126kV Dry-Type Transformer Bushings drawing

145kV-170kV Dry-Type Transformer Bushings drawing

252kV-550kV Dry-Type Transformer Bushings drawing

 

Quality & Testing
Every bushing undergoes rigorous testing, including bending load tests to ensure structural integrity under operational stress. For example, 72.5kV to 145kV units are tested with loads up to 4000N, while 500kV units (363kV series) withstand up to 5000N.

Get in Touch with Liyond

We're here to help! Connect with our team for expert support and personalized solutions.

Power your projects with long-lasting switchgear and switchgear components from Liyond.

We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.          Privacy Policy
Reject Accept
error: Content is protected !!