Our Dry-Type Capacitive Wall Bushings are engineered for power stations and substations, providing a high-performance solution for conductors passing through grounded partitions or walls while maintaining superior insulation to ground.
Insulation Technology: Utilizes dry-type capacitive cores for stable electric field distribution without the risk of oil leakage.
Voltage Range: Specifically designed for system voltages including 72.5kV, 126kV, and 252kV.
Mechanical Integrity: Certified for bending test loads up to 5000 N for 252kV/2000A configurations.
Dielectric Performance: Maintains a low dielectric loss tangent (tan δ) of ≤ 0.6% and partial discharge levels ≤ 10pC at 1.05Ur/√3
These bushings are tested to meet rigorous international standards for electrical and mechanical endurance.
Table I: Electrical Performance of Dry-type Capacitive Wall Bushings
| Nominal System Voltage (Un) kV | 110 | 220 | 330 | 420 | 500 | |
| Rated Voltage (Ur) kV | 126 | 252 | 363 | 420 | 550 | |
| Highest Phase Voltage of Equipment (Ur/√3) kV | 73 | 146 | 210 | 242 | 317 | |
| 60s Power-Frequency Withstand Voltage | Dry kV (r.m.s) | 230 | 460 | 570 | 695 | 870 |
| Wet kV (r.m.s) | 230 | 460 | 535 | 680 | 790 | |
| Lightning Impulse Withstand Voltage | Full Wave kV (Peak) | 550 | 1300 | 1425 | 1425 | 1800 |
| Dielectric Loss Angle Tangent % | Max Value (Not Greater Than) 40.5kV ~ 363kV | 1.05Ur/√3 -Ur: 0.1 | ||||
| Max Value (Not Greater Than) 420kV ~ 550kV | 1.05Ur/√3 · Measured: 0.6 | |||||
| Partial Discharge at U_r (Not Greater Than) pC | 10 | |||||
Table II: Bending Test Load Table
| Rated Voltage Ur (kV) | Rated Current Ir A | ||
| Ir ≤ 800 | 800 < Ir ≤ 1600 | 2000 ≤ Ir | |
| Bending Test Load N (N) | |||
| 126 | 2000 | 2000 | 4000 |
| 252 | 4000 | 4000 | 5000 |
Overall Dimensions
Why Specify Our Dry-Type Bushings?
Unlike traditional oil-impregnated paper (OIP) bushings, our dry-type capacitive technology eliminates explosion risks and environmental hazards from oil leaks. With a focus on technical precision, we ensure that every unit meets specific creepage distance and withstand voltage requirements for diverse global climates, including high-pollution environments
Please provide the following details when placing an order:
1.Product Model Number
2.Rated Voltage and Rated Current
3.Creepage Distance
4.Grounding Section Dimensions (for Current Transformer installation)
5.Other Special Requirements