CKG3-12 series high voltage vacuum AC contactor is suitable for AC 50-60Hz, the main circuit rated working voltage is 12KV, the rated current is below 630A in the power network for long distance connection and disconnection line and frequent start. It is suitable for controlling AC motors, and it is more suitable to replace the vacuum circuit breaker with fuses and various protection devices.
1. High arc extinguishing capacity
2. Good pressure resistance
3. High operating frequency
4. Long life
5. No arcing out
6. Small volume
7. Light weight
8. Longer maintenance intervals
PS: vacuum contactor switch with special requirements, specifications and dimensions that need to be improved can be designed and manufactured according to user requirements.
Applying Ambient Conditions:
1. The ambient air temperature is not higher than +40°C, not lower than -10°C;
2. The altitude of the installation site should not exceed 1000 meters for the ordinary type and 4000 meters for the plateau type;
3. The relative humidity of the air, the monthly average maximum relative humidity of the wettest month is 90%, the monthly average minimum temperature of the month is 25C, and the condensation on the product surface due to humidity changes is considered;
4. There is no obvious shaking and shock vibration occasions.
5. In a place without explosion hazard, and there is no gas and dust (including conductive dust) sufficient to corrode insulation;
6. Places without rain and snow.
|
Main circuit rated voltage (kV)
|
12
|
12
|
12
|
12
|
|
Main circuit rated current (A)
|
160
|
250
|
400
|
630
|
|
Main circuit Joint capacity (A/100 times)
|
1600
|
2500
|
4000
|
6300
|
|
Main circuit on-off capability (A/10 times)
|
1280
|
2000
|
3200
|
5000
|
|
Ultimate breaking capacity (A/3 times)
|
3200
|
4000
|
4500
|
6300
|
|
Mechanical life (times)
|
1000000
|
1000000
|
1000000
|
1000000
|
|
Mechanical lock life (times)
|
100000
|
100000
|
100000
|
100000
|
|
Main circuit power frequency withstand voltage (kV)
|
32
|
32
|
32
|
32
|
|
Auxiliary circuit power frequency withstand voltage (kV)
|
2.5
|
2.5
|
2.5
|
2.5
|
|
Control circuit frequency withstand voltage (kV)
|
2
|
2
|
2
|
2
|
|
Rated operating frequency (time/h)
|
300
|
300
|
300
|
300
|
|
Mechanical lock operating frequency (time/h)
|
30
|
30
|
30
|
30
|
|
Contact opening (mm)
|
5±0.5
|
5±0.5
|
5±0.5
|
5±0.5
|
|
Overtravel (mm)
|
1.5±0.3
|
1.5±0.3
|
1.5±0.3
|
1.5±0.3
|
We're here to help! Connect with our team for expert support and personalized solutions.
Check out these related products you might also be interested in.