The SC(B)10 series epoxy resin cast dry-type transformer is designed for indoor applications where fire safety, environmental cleanliness, and minimal maintenance are critical. With a 35kV voltage class, this transformer is ideal for use in high-rise buildings, hospitals, shopping centers, schools, underground substations, power plants, oil fields, and mining operations. It fully complies with GB1094.1-5 and GB1094.11 standards, ensuring reliable performance in demanding environments.
Fire Safety & Environmental Protection
Epoxy resin cast construction ensures self-extinguishing properties, making the transformer safe for installation in fire-sensitive areas. No risk of oil leakage, fully environmentally friendly.
Low Loss & High Efficiency
Optimized core and winding design results in low no-load and load losses, reducing operational costs over the transformer’s lifetime.
Low Noise Level
Special core structure and resin encapsulation significantly reduce operational noise, suitable for noise-sensitive environments.
High Reliability
Thousands of units in service demonstrate performance reaching international reliability standards.
Excellent Moisture Resistance
Can operate normally in 100% humidity conditions. Requires no pre-drying before restarting after shutdown.
Maintenance-Free
No oil or cooling medium required. Minimal maintenance reduces total cost of ownership.
Core
High-permeability grain-oriented cold-rolled silicon steel.
45° full miter multi-step core joints.
Square tube pull-rod structure with core column bound by insulating tape.
Special resin coating on core surface prevents rust and moisture ingress.
Effectively reduces no-load loss, excitation current, and noise.
Windings (Foil-Wound Low Voltage Coils)
Low voltage windings use full-section copper foil with Class F insulation.
Wound on dedicated foil winding machines for uniform ampere-turn distribution.
Eliminates issues such as high short-circuit stress, poor heat dissipation, and welding inconsistencies found in traditional wire-wound coils.
Coil ends are resin-sealed and cured for enhanced moisture and contamination protection.
Temperature Control System
Equipped with BWDK series digital temperature controller.
Temperature sensors embedded in the upper part of each low voltage coil.
Provides automatic three-phase temperature monitoring, display, over-temperature alarm, and trip functions.
| Rated Capacity (kVA) | Voltage Combination | Connection Symbol | Loss (kW) | No‑Load Current (%) | Short‑Circuit Impedance (%) | Weight (Unit Only) (kg) | Weight (With Enclosure) (kg) | |||
| High Voltage (kV) | HV Tapping Range | Low Voltage (kV) | Losses (Load 120℃) | Losses (No-load) | ||||||
| 50 | 38.5 35 |
±5% ±2×2.5% |
0.4 | Yyn0 Dyn11 |
1.43 | 0.45 | 2.80 | 6 | 720 | 770 |
| 100 | 2.09 | 0.63 | 2.4 | 890 | 950 | |||||
| 160 | 2.83 | 0.792 | 1.8 | 1000 | 1060 | |||||
| 200 | 3.33 | 0.88 | 1.8 | 1260 | 1320 | |||||
| 250 | 3.8 | 0.99 | 1.60 | 1420 | 1480 | |||||
| 315 | 4.51 | 1.18 | 1.6 | 1730 | 1790 | |||||
| 400 | 5.42 | 1.38 | 1.4 | 1840 | 1900 | |||||
| 500 | 6.65 | 1.62 | 1.4 | 2200 | 2270 | |||||
| 630 | 7.7 | 1.86 | 1.2 | 2630 | 2700 | |||||
| 800 | 9,12 | 2.16 | 1.2 | 3260 | 3330 | |||||
| 1000 | 10.45 | 2.43 | 1 | 3990 | 4060 | |||||
| 1250 | 12.73 | 2.84 | 0.9 | 4470 | 4540 | |||||
| 1600 | 15.49 | 3.24 | 0.9 | 5570 | 5640 | |||||
| 2000 | 18.24 | 3.83 | 0.9 | 6410 | 6480 | |||||
| 2500 | 21.85 | 4.46 | 0.9 | 6930 | 7030 | |||||
| Rated Capacity (kVA) | Outline and Mounting Dimensions (mm) | ||||
| L | W | H | C1 | C2 | |
| 50 | 1180 | 890 | 1050 | 660 | 660 |
| 100 | 1250 | 900 | 1350 | 660 | 660 |
| 160 | 1540 | 920 | 1660 | 820 | 820 |
| 200 | 1620 | 920 | 1750 | 820 | 820 |
| 250 | 1650 | 940 | 1800 | 820 | 820 |
| 315 | 1670 | 940 | 1850 | 820 | 820 |
| 400 | 1720 | 1150 | 1900 | 820 | 820 |
| 500 | 1810 | 1150 | 1940 | 820 | 1070 |
| 630 | 1850 | 1150 | 1990 | 820 | 1070 |
| 800 | 1990 | 1150 | 2010 | 820 | 1070 |
| 1000 | 2020 | 1150 | 2040 | 1070 | 1070 |
| 1250 | 2080 | 1150 | 2120 | 1070 | 1070 |
| 1600 | 2130 | 1150 | 2320 | 1070 | 1070 |
| 2000 | 2180 | 1150 | 2480 | 1070 | 1070 |
| 2500 | 2200 | 1150 | 2600 | 1070 | 1070 |
| 3150 | 2580 | 1320 | 2610 | 1070 | 1070 |
| 4000 | 2680 | 1320 | 2650 | 1070 | 1070 |
| 5000 | 2890 | 1350 | 2680 | 1475 | 1070 |
| 6300 | 2980 | 1700 | 2800 | 1475 | 1070 |
To ensure accurate selection and timely delivery, please provide the following details when placing an order:
Product Model
Rated Capacity (kVA)
High Voltage / Low Voltage Ratings (kV)
High Voltage Tapping Range
Number of Phases (typically 3-phase)
Frequency (50 Hz)
Connection Symbol (Yyn0 or Dyn11)
Enclosure Requirements (if applicable)
Safe for Indoor Use: Fire-resistant, non-toxic, and self-extinguishing.
Energy Efficient: Low losses contribute to lower operating costs.
Environmentally Friendly: No oil, no risk of leakage or contamination.
Proven Reliability: Designed and tested to meet rigorous international standards.
Easy Installation: Compact footprint, suitable for direct installation at load centers.
We're here to help! Connect with our team for expert support and personalized solutions.
Check out these related products you might also be interested in.
Get A QuotePower your projects with long-lasting switchgear and switchgear components from Liyond.