24kV SF6-Free Gas Insulated RMU Switchgear | Liyond Electric
Home/Medium Voltage Switchgear/Ring Main Unit (RMU)/24kV SF6-Free Environmental-Friendly Gas Insulated Ring Main Switchgear (RMU)

24kV SF6-Free Environmental-Friendly Gas Insulated Ring Main Switchgear (RMU)

This series of indoor, three-phase AC medium-voltage (MV) environmental-friendly gas-insulated ring main units (RMU) represents our newly developed generation of distribution equipment. Developed in response to global green environmental protection concepts and strict decarbonization grid regulations, this switchgear serves as a premier alternative to traditional SF6 gas-insulated equipment.

By utilizing clean dry air insulation within a hermetically sealed stainless steel air box combined with a vacuum interrupter for load breaking, this series achieves zero greenhouse gas emissions while fully meeting GB and IEC technical standards.

The integration of our flexible vacuum load break switch (LBS) allows for an ultra-compact tank structure. The phase-to-phase distance can be configured from 210mm to 230mm to fit standard panel widths, or can be customized and evaluated based on specific customer enclosure requirements, ensuring seamless compatibility for various retrofitting project needs.

Electrical ProductsElectrical Products

Core Product Features of Gas Insulated Ring Main Switchgear

1. Advanced Safe Interlocking & Visibility

Dual Isolation Breakouts: The integrated switch features distinct and visible “double” isolation breakouts to ensure ultimate operator safety during maintenance.

Modular “Five-Prevention” Interlock: Truly prevents misoperation. The lower compartment door features an emergency unlocking device and can only be opened when the main circuit is fully grounded. Conversely, the grounding switch can only be tripped and the switch closed after the lower door is secured.

2. Miniaturized & Highly Flexible Design

Compact Footprint: Due to the optimized space configuration of the inner vacuum LBS, the standard air box width can be compressed down to 450mm–500mm.

Customization Evaluation: While the standard phase pitch supports compact layouts, the structural dimensions, scheme layout, and expansion options (top or side expansion) can be tailored to specific project blueprints.

High Versatility: The upper and lower isolation schemes share a component utilization rate of over 90%, ensuring high product stability and strong versatility for stock management.

XGN-24-630-20 Eco-Friendly Gas-Insulated Vacuum Load Break Switch (with Integrated 3-Position Disconnector)

Operating Environment

1. Ambient Air Temperature: Upper limit +40℃, lower limit -50°C.
2. Relative Air Humidity: Daily average ≤ 95%, monthly average ≤ 90%.
3. Altitude: Standard design up to 1500 meters. Special structural adjustments for the air box are available for high-altitude installations at 2000 meters or above upon request.
4. Earthquake Resistance: Intensity does not exceed level 8.
5. Site Conditions: Applicable for locations free from fire, explosion, severe contamination,
chemical corrosion, and violent vibrations.

 

Technical Specifications of Environmental-Friendly Gas Insulated Ring Main Switchgear

Parameter Load Switch Unit Value
Rated Voltage 24kV
Insulation Medium Clean Dry Air
Arc Quenching Medium Vacuum Interrupter
Rated Current 630A
Rated Frequency 50 / 60Hz
Power Frequency Withstand Voltage (Phase-to-Phase, Earth / Switching Contact) 65kV / 79kV
Lightning Impulse Withstand Voltage (Phase-to-Phase, Earth / Terminal) 125kV / 145kV
Rated Short-Time Withstand Current (4s) 20kA
Rated Short-Circuit Making Current (Peak) 50kA
Active Load Interruption Times (630A) 1000 times
Rated Inflation Pressure (at 20℃) 0.04 MPa
Annual Leakage Rate < 0.01% / year
Mechanical Lifespan (Load Switch / Disconnector) 5000 times
Mechanical Lifespan (Grounding Switch) 3000 times
Protection Level (Cabinet Body Shell / Air Box) IP4X / IP67
Standard Dimensions (Width x Depth x Height) 450mm x 950mm x 2100mm

According to International Standards

The product design, manufacturing, and type testing strictly comply with the following standards:

GB/T 11022 / IEC 62271-1: Common technical requirements for high-voltage switchgear and controlgear standards.

GB/T 3906 / IEC 62271-200: AC metal-enclosed switchgear and control equipment.

GB/T 3804 / IEC 62271-103: High-voltage AC load switches.

GB/T 1985 / IEC 62271-102: High-voltage AC disconnect switches and grounding switches.

Ordering Instructions

When placing an order or requesting a technical evaluation, please provide the following information:

1. Main circuit diagram, panel arrangement diagram, and floor plan layout.

2. Secondary circuit schematic diagram of the switchgear cabinet.

3.Specific isolation configuration requirement (Upper Isolation or Lower Isolation scheme).

4. Expansion requirements for the air box tank (Top Expansion or Side Expansion option).

5. Any special or harsh environmental operation conditions (e.g., high altitude above 2000m).

Get in Touch with Liyond

We're here to help! Connect with our team for expert support and personalized solutions.

Power your projects with long-lasting switchgear and switchgear components from Liyond.

We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.          Privacy Policy
Reject Accept
error: Content is protected !!