LYE102 JN15-12/D31.5 AC Medium Voltage Motorized Earthing Switch Ground Knife

JN15-12D-31.5 earthing switch

 

  • LYE102 JN15-12/D31.5 AC Medium Voltage Motorized Earthing Switch Ground Knife

    JN15-12/31.5 indoor AC high voltage earthing switch is an advanced level product with high-tech parameters performance. After comprehensive evaluation,it conforms to GB1985 and IEC62271 standard, applies to power system of 12kV and three-phase AC 5OHz. It owns short-circuit making capacity to protect other electric equipment not being damaged. Can be used with various high voltage switchgear, alsc play a protective role in the high-voltage electrical equipment overhaul.

    Main features

    1. Simple installation, with a combination of the main earthing switch, without changing the original install structure of earthing switch.

    2. It can be achieved freely switch for manually operated and electrically operated.

    3. It is safe and reliable, attempts to prevent the conversion function can be realized on control and protection for the motor.

     

  • LYE102 JN15-12/D31.5 AC Medium Voltage Motorized Earthing Switch Ground Knife

    Item Unit Data
    Rated voltage kV 12
    Rated short-time withstand current kA 31.5
    Rated short-circuit duration s 4
    Rated short-circuit making current kA 80
    Rated peak withstand current kA 80
    Rated insulation level PF withstand voltage (1 min) kV Phase to earth Phase to phase 42
    Lightning impulse withstand voltage 75
    Mechanical endurance times 2000

     

    Outline Dimension Drawing

    After JN15-12/D31.5 Motorized earthing switch is installed, according to the following steps for debugging:

    1. Read the specification of REC-10-HB switchgear electric control device.
    According to the wiring terminal diagram of REC-10-HB switchgear electric control device sample, connect electric earthing switch wiring terminal in accordance with the electrical diagram terminal number.

    2. Motor earthing switch terminal is pluggable terminal block. When complete connection,before testing power-on, user should pull out terminal, hang measured terminal 1.2 foot motor power During press the switch knob of electric control device,need insure 1 foot is positive power(VDD), ) foot is negative power(GnD ). If wiring is correct, then plug termina

    3. By test, observing whether the indicator light function of ERC-10-HB switchgear electric control device is correct. If not correct, please check the correctness of terminal and in place of signal source of switch opening, closing is correct or not.

    4. Manual operate earthing switch opening-closing, observing whether the display of electric control device is correct. If correct, can debug by motor operation.

    5. Special note of motor operation test: switchgear electric control device send intruction of earthing switch opening or closing. If the operating conditions are met, then will perform earthing switch opening or closing operation, observing whether the mechanism rotation direction is correct. If mechanism rotation direction is opposite, user should immediately turn off the power or press the scram button on device to stop the current operation, try again after changing moter positive and negative terminals. If the operating conditions are not met,(such as the interlocking signal of control device 11 foot is not correct), control device will not work properly, the user should settle accordingly to meet the operating conditions and try again.

    6. The switch off motion and the signal of the opening and closing reaching of the electric earthing switch are subject to the connect between operating shaft cam arrangement and microswitch. When electric earthing switch is connected with cabinet interlock, we should offer electric control device power supply, Combining with the control device opening and closing indicator light, manually adjust the opening and closing reaching of earthing switch(note:Wher the spring of earthing switch is just over dead point,the operating handle should seize up immediately), observe whether the control device opening and closing indicator light can synchronously indicate or not. Otherwise, we should adjust the upper and lower position of twin thread screw in the interlock to make them synchronously. If interlock position error is too big to reach synchronic we should make a fine adjustment in position between micro-switch and cam, and then observe control device just to make the corresponding indicator light.

    Motorised earth switch controllers ERC-10-HB-A1 

    WIRING INSTRUCTIONS OF MOTORIZED EARTHING SWITCH

    1. When switch equipment motorized control device terminal No. 3 and No. 4 corresponds to terminal No. i positive and No. 2 cathode, be careful not to reverse the polarity of the power supply to avoid damage to the motor. Through the debugging to observe whether the rotates direction of earthing switch operating shaft gear met the switch’s opening, closing state, otherwise swap the positive and negative

    2.If operate motorized earthing switch separately(not loading), switch equipment motorized control device terminal No. 11 and No. 10 (0V common terminal) short.

     

LYE104 JN15-24/D31.5 24kV Medium Voltage Electric Motorized Earthing Switch 24kV

JN15-24D earthing switch

 

  • LYE104 JN15-24/D31.5 electric earthing switch 24kV

    JN15-24/D31.5 type indoor high voltage grounding switch is a grounding switch developed by our company. This product has the features of simple and compact structure, reliable technical performance, etc. It meets the requirements of GB1985-2004 “AC High-voltage Disconnectors and Grounding Switches” and IEC62271-102:2002, and is suitable for indoor 24kV three-phase AC 50(6O)Hz power system. It has the ability of short-circuit shutdown to protect the other electrical equipments in the switchgear from being damaged, and can be used together with all kinds of high-voltage switchgears as grounding protection for high-voltage electrical equipments during maintenance. It can be used with all kinds of high-voltage switchgear as the grounding protection of high-voltage electrical equipment during maintenance.

     

    Model and Meaning

    Normal usage environment
    1. The altitude does not exceed 1000m;
    2. Ambient air temperature: upper limit +40°C; lower limit -25°°C;
    3. Relative humidity: the daily average value is not greater than 95%; the monthly average value is not greater than 90%;
    4. The earthquake intensity does not exceed 8 degrees;
    5. Pollution level: II.

  • LYE104 JN15-24/D31.5 electric earthing switch 24kV

    Technical Parameter

    Item Unit Data
    Rated voltage kV 24
    Rated short-time withstand current kA 31.5
    Rated short-circuit duration s 4
    Rated short-circuit making current kA 80
    Rated peak withstand current kA 80
    Rated insulation level PF withstand voltage (1 min) kV Phase to earth Phase to phase 42
    Lightning impulse withstand voltage 75
    Mechanical endurance Times 2000

    Outline Dimension Drawing

    Note:

    1. Three phase rigid position’s different period not more than 3mm.
    2. The position of each phase skew not more than 2mm.
    3. Insulation Monitori ,Power Frequency Voltage-Withstand 42kv/min
    4. Each measurement of Contact Resistance not more than 60u.

    WIRING INSTRUCTIONS OF MOTORIZED EARTHING SWITCH

    1. When switch equipment motorized control device terminal No. 3 and No. 4 corresponds to terminal No. i positive and No. 2 cathode, be careful not to reverse the polarity of the power supply to avoid damage to the motor. Through the debugging to observe whether the rotates direction of earthing switch operating shaft gear met the switch’s opening, closing state, otherwise swap the positive and negative

    2.If operate motorized earthing switch separately(not loading), switch equipment motorized control device terminal No. 11 and No. 10(0V common terminal) short.

     

     

KYN28-12 Medium Voltage Removable Metal-clad Switchgear Cabinet Withdrawable Enclosure

KYN28A-12 switchgear

  • Summary

    KYN28-12(GZSZ) removable metal-clad switchgear is one medium voltage switchgear, which applies to three -phase 50Hz, rated voltage 12kV, working current reaches to 4000A of indoor power distribution equipment, mainly as a secondary substation by electric power plants, industrial and mining enterprises, power distribution and power systems, power transmission and high-voltage motor starters and other places for control, protection and monitoring.

    Structure Description

    1. Switchgear accoding to GB3906 and IEC298 armored metal- emclosed switchgear standard designed by the cabinet and the overall cabinet be composed of housing and withdrawable part (handcart) two parts, the cabinet made of high quality cold-rolled steel and high quality aluminum deposited zinc plate by precision CNC macjing (some parts with high precision laser cutting machine and  sprcial mold), doble side process forming, connected together by high strengh bolts, nuts, rivet nuts, steel rivets, cabinet low pressure chamber, circuit breakers chamber, bus room, cable room unit cell effectively separated, and each unit has separate pressure relief channnel, with good relief and ventilation, indoor another cable set 10*60mm main ground bus.

    2.With full assembled cabinet, compact structure, equipped with a variety of domestic and international mainstream vacuum circuit breaker, voltage transformers, surge arresters, the varivles fuses, isaolation in the home -handcart, all the same functionality handcart unit, have a good interchangeability, easy operation and replacement.

    Main characteristics

    1. It has a simple and effective ‘Five Anti’ interlock to prevent misuse .

    2. The cabinet can be used with ZN63A(VS1), VD4, ZN21, 3A1-1, VB2 and VEP vacuum circuit breaker, VC7 vacuum contactor, load switch and disconnecting switch so on .

    3. It can be used with voltage transformer handcart, metering handcart, isolating handcart, station used earthing handcart,of which are with same function and interchangeable .

    4. The cabinet can be installed against the wall, the maintenance can be done in the front of the cabinet, it can reduce the footprint.

    5. The circut breaker room and cable roon can separetely equipped with heater to prevent the condensation and corrosion.

    6. The cable room is spacious, and it can be connected to many cables.

    7. Switchgear enclosed protection rating reaches to IP4X. Eaxch compartment level of protection is IP2X.

    Environmental conditions
    1. Ambient temperature: +42℃— – 25℃
    2. Altitude≤1000m
    3. Ambient temperature: the monthly average relative humidity is not more than 90%, the daily average relative humidity is not more than 95%
    4. It is suitable for harsh places such as no fire, explosion hazard and gas that is enough to corrode metal and destroy insulation; places without severe vibration, bumps and vertical inclination not exceeding 8 degrees.

  • Technical Parameters

    Item Unit Parameters
    Rated voltage KV 12~24
    Rated current HZ 50
    Rated current of circuit breaker A 630\2000
    Rated current of switch cabinet A 630\2000
    Rated current of dynamic stability (4S) KA 16\20\25\31.5\40\50
    Rated current of dynamic stability (peak) KA 40\50\63\80\100\125
    Rated short circuit drop-out current KA 16\20\25\31.5\40\50
    Rated short circuit making current (peak) KA 40\50\63\80\100\125
    Rated insulation level 1min power frequency withstand voltage KA 24 32 42
    lighting impulse withstand voltage KA 40 60 75
    Protection degree IP2X shell: IP4X, it is IP2X when compartment and circuit breaker room is open

    Shape and installation dimensions

    KYN28 switchgear installation diagram

    Cabinet outline dimensions(mm)(not including door)

    Height Width Depth
    2300 800 1500
    2300 1000 1500

     

    Ordering Instructions

    The following technical information should be provided when ordering:
    1. The number of the main circuit scheme diagram, the purpose and the main wiring system diagram, the layout and arrangement diagram of the power distribution room, etc.
    2. Requirements for control, measurement and protection functions of switchgear and requirements for other locking and automatic devices.
    3. The model, specification and quantity of the main electrical components in the switchgear.
    4. If bus bridge connection is required between switchgear or incoming cabinet, specific requirements data such as the rated current carrying capacity of the bus bridge, the span of the bus bridge, and the height from the ground should be provided.
    5. When the switchgear is used in special environmental conditions, it should be explained in detail when ordering.
    6. Other special requirements.

High Voltage 2000A Fixed Contact For Indoor Vacuum Circuit Breaker

Model No.: LYB105

2000A fixed contact for vacuum circuit breaker LYB105

2000A fixed contact for vacuum circuit breaker LYB105

  • High Voltage 2000A Fixed Contact For Indoor Vacuum Circuit Breaker

    Fixed contacts are used as auxiliary parts in KYN type armored metal-enclosed switchgear and JYN type spaced metal-enclosed switchgear, and can also be used in other trolley type switchgear, which has the characteristics of reliable contact, excellent electrical performance and convenient operation. It is applicable to KYN and JYN type switchgear and other switchgear as primary circuit connection.

    Fixed contacts are installed in the switch cabinet contact box, 6 in one switch cabinet, 2 in each of ABC three-phase and one-phase.Used in circuit breakers or compound switches, the fixed contact is fixed, and the circuit breaker or switch is opened and closed by the movement of the moving contact, and even plays the role of breaking the current.

    Model No.: LYB105

    Rated current 2000A
    Material T2 red copper
    Application vacuum circuit breaker
    The minimum quantity 10pcs
    Payment terms T/T, L/C, Western Union

    Features:
    1. Thick and durable, fine workmanship, safe and reliable
    2. Copper rod forming, copper plated with silver, anti-oxidation, longer service life

     

  • 2000A fixed contact for vacuum circuit breaker LYB105

    2000A fixed contact for vacuum circuit breaker LYB105

  • [Download not found]

2000A Silver plated Fixed Contact For Vacuum circuit breaker LYB105