Fault indicator series
-
-
APJD-EKL3 Panel type short circuit grounding fault indicator
Panel type short circuit grounding fault indicator
● Product Overview
Panel type short-circuit ground fault indicator is supporting installation ring net switch
in the power distribution network system, Cable branch box, box changes, Used to indicate the corresponding
cable segment of single-phase earth fault of short circuit and a real-time monitoring devices. Line fails, the staff
can use indicator alarm indication, quickly determine the fault section, and find out the fault point. At the same time,
the alarm fine real-time can be sent to the monitoring center server, In monitoring the computer screen
shows a fault area and the specific location, guide the patrol personnel to quickly determine the fault section
and find out the fault point.The indicators provide the best way to solve the problem of troubleshooting.
To improve the work efficiency and shorten the blackout time , quickly restore power, improve power supply
reliability and economic benefit, it is of great significance.
●The main function
1.Short circuit alarm indicator
2. Grounding alarm indication
3. Automatic reset
4. Manual reset
5. Remote alarm reset
-
APJD-EK14 Panel type short circuit grounding fault indicator
Panel type short circuit grounding fault indicator
● Product Overview
Panel type short-circuit ground fault indicator is supporting installation ring net switch
in the power distribution network system, Cable branch box, box changes, Used to indicate the corresponding
cable segment of single-phase earth fault of short circuit and a real-time monitoring devices. Line fails, the staff
can use indicator alarm indication, quickly determine the fault section, and find out the fault point. At the same time,
the alarm fine real-time can be sent to the monitoring center server, In monitoring the computer screen
shows a fault area and the specific location, guide the patrol personnel to quickly determine the fault section
and find out the fault point.The indicators provide the best way to solve the problem of troubleshooting.
To improve the work efficiency and shorten the blackout time , quickly restore power, improve power supply
reliability and economic benefit, it is of great significance.
●The main function
1.Short circuit alarm indicator
2. Grounding alarm indication
3. Automatic reset
4. Manual reset
5. Remote alarm reset
-
APJD-EKL2 Fault indicator
Cable type fault indicator
●Product Overview
APJD – EKL2 fault indicator (hereinafter referred to as the indicator) is the latest development of high-tech products,
suitable for cable connection box, ring net switch cabinets and other cable grounding fault detection and instructions
Line has a ground fault occurs, the. indicator to detect the short circuit current and computing, memory fault state,
the red lights started flashing. After automatic reset time, the red lights stop flashing, indicator automatic reset, and
clear fault record.
-
APJD-EKL1Series overhead type fault indicator
Overhead type fault indicator
●Product Overview
APJD – EKL1 series overhead type fault indicator mounted on a 6-35 kv power transmission and distribution lines,
used to indicate a fault current circulation of the device Line fails, the patrol personnel can use red alarm indicator
shows quickly determine the fault section and find out the fault point. Greatly improve the work efficiency and shorten
the blackout time, improve the reliability of power supply effectively. The company on the basis of summarizing the
existing fault detection device, puts forward a new method of fault detection, fault detection device detection method is novel,
not only stable and reliable performance, and installation and landed are extremely easy and convenient.
-
-