DXN8D HV Switchgear Voltage Indicator Live Display Device–Holes Size OF 58*31.5MM
-
Indoor high-voltage charged display device consists of three sensors and a display connected by wires. It is suitable for indoor high voltage electrical equipment under rated frequency 50Hz and rated voltage 40.5KV. Not only can reflect the circuit charged condition, but also with the electromagnetic lock. To achieve the mandatory locking of switch handles, valves, etc.. The charged display and mandatory locking are controlled by the same high-voltage signal, but the circuit system is independent of each other, do not interfere with each other, as long as the high-voltage circuit is energised, even if the display circuit and the locking circuit fail at the same time, the electromagnetic lock is still in the locking state to prevent misoperation, the purpose of the erroneously energised intervals.
This product is used to provide a switchgear equipment circuit voltage information at the installation status to the operator. As a result of its internal circuitry of low-power light-emitting element, which makes low power consumption, more stable performance and higher reliability. For the user test double-loop phase conveniently, indicator(recommend type) panel setting the end of the test phase, meanwhile the frame of indicator (recommend type) shell adopts front end removable. And the user can change the indicator without opening the indicator shell.
Widely used for indoor 7.2, 12, 24, 40.5kV, frequency of 50Hz high voltage electrical equipment, and supporting the use of the voltage sensor, it can reflect the high voltage live situation, and voltage sensor support, but also to improve the anti-error performance ancillary products.
Executive standard
1.GB25081-2010 HV live display device(VPIS)
2.DL/T533-93 condensation and pollution test condition for indoor AC HV switchgear and components
3.IEC61958:2000 HV prefabricated switchgear assembly and control assembly-live displaying device
Applying environment conditions
1.Environment temperature: upper limit value not more than +40℃,lower limit value not lower than -25℃, special area not lower than -35℃.
2.Sea level: no more than 1000m.
3.Atmospheric conditions: RH daily average value not more than 95%, month average value not more than 90%, steam pressure daily average value not more than 2.2kPa, month average value not more than 1.8kPa.
4.Environment condition: no obvious filth, no flammable, no explosive chemical etcing and salt fog place.
-
Outline installation hole dimension
Voltage indicator selection table